Dark Light

OSCA Series

OSCA Series

Features:

  • Off-line bypass oil cleaners for high flow rates and for large tank volumes. Based on the SU-series , SS-series and AL-series filter housings.
  • Ideal for:
    – Maintenance service activities.
    – Very large oil volumes up to 50.000 litres.
    – High viscosity oil.
  • Effectively removes all the particles that are usually very difficult to remove with conventional filters and performs a total cleaning of the oil by removing solid particles, absorbing water and eliminating sludge and other oil oxidation residues.
  • All systems are fully equipped and come with a washable metal suction filter, control gauges, a breaker switch ,Quicktoron air removal (Without the water glycol model) and a drain tap.
  • Standard units have a flow range from 6 lit/min up to >60 lit/min, and can be suitable for very large oil volumes (>50.000 litres).
  • Optional equipment: timer, automatic drain function, pressure switch ,vacuum switch ,control panel,etc.
image002

Benefits:

  • Prevents trouble to the hydraulic equipments.
  • Improves machine reliability and productivity.
  • Longer life of all hydraulic components, pumps, valves and other equipment.
  • Extends oil life by up to 40.000 hrs.
  • Very important reduction of oil consumption and resulting waste oil.
  • Discharges the full flow filters and extends their life.
  • Important reduction of maintenance costs.
image004

Typical applications:

  • Large volume systems.
  • Lube systems and high viscosity systems.
  • Perfect for service flushing and for cleaning fresh oil when (re-)filling a hydraulic system.
  • Hydraulic testing lines.
  • Heavy industrial press.
1

CS-SU type

2

CS-SU -PF type

3

CS-SS type

4

CS-SS Large capacity type

5

CS-AL type

6

CS-AL-PF type

* All circumstance should be considered before selecting a suitable oil cleaner and flow rate.
Please consult with your distributor for model detail.

SU type

Standard models for the mineral oil<Install elements/M100·20430·βз=929>

Model/Specifications Article nr Motor Flow rate
/min
Thread

BSPT

Dimension

mm

Weight
(Dry)
Tank

capacity

Nr.of

elements

200V 100V Power(KW)·
Cycle(
Hz)
50Hz 60Hz IN OUT W L H kg Liter
CS-SU102-1RQ 2 15202 15203 0.20·50/60 6.0 7.2 1/2 1/2 406 652 885 58 >1,200
CS-SU102-2RQ 4 15222 15223 0.40·50/60 12.0 14.4 3/4 3/4 406 993 885 90 >2,400
CS-SU103-1RQ 3 15302 15303 0.40·50/60 9.0 10.8 1/2 1/2 406 652 1030 61 >1,800
CS-SU103-2RQ 6 15322 15323 0.75·50/60 18.0 18.0 1″ 1″ 406 993 1030 96 >3,600
CS-SU103-3RQ 9 15332 15333 0.75·50/60 24.0 28.8 1″ 1″ 406 1273 1030 130 >5,400
CS-SU103-4RQ 12 15342 15343 1.50·50/60 30.0 36.0 1″ 1″ 406 1526 1030 165 >7,200
Replacement

elements

·E100(20470/5μm)·X100(25450/10μm)·D100(20000/3μm)·WE100(20450/Only Water absorber)

Models for the water glycol <Install elements/WG100·25470/10μ>

Model/Specification Article nr Motor Flow rate
/min
Thread

BSPT

Dimension

mm

Weight
(Dry)
Tank

capacity

Nr.of

elements

200V 100V Power(KW)·
Cycle(
Hz)
50Hz 60Hz IN OUT W L H kg Liter
CS-SU102W-1R 2 15252 15253 0.20·50/60 4.2 5.0 1/2 1/2 406 652 885 58 >600
CS-SU102W-2R 4 15262 15263 0.40·50/60 6.0 7.2 3/4 3/4 406 993 885 90 >1,200
CS-SU103W-1R 3 15352 15353 0.20·50/60 4.2 5.0 1/2 1/2 406 652 1030 61 >900
CS-SU103W-2R 6 15374 15375 0.40·50/60 9.0 10.8 1″ 1″ 406 993 1030 96 >1,800
CS-SU103W-3R 9 15382 15383 0.75·50/60 12.0 14.4 1″ 1″ 406 1273 1030 130 >2,700
CS-SU103W-4R 12 15432 15433 0.75·50/60 18.0 18.0 1″ 1″ 406 1526 1030 165 >3,600
Replacement
element
DWG100(25480/5μm)

SU-PF type

Standard models for the mineral oil<Install elements/M100·20430·βз=929 Install pre-filters/PF20·22289·20μ >

Model/specification Nr.of Article nr Motor Flow rate
/min
Thread

BSPT

Dimension

mm

Weight
(Dry)
Tank

capacity

elements 200V 100V Power(KW)·
Cycle(
Hz)
50Hz 60Hz IN OUT W L H kg Liter
CS-SU103-1RQ-3PF20 15310 15311 0.40·50/60 9.0 10.8 1/2 1/2 406 932 1030 87 >1,800
CS-SU103-2RQ-3PF20 15620 15621 0.75·50/60 18.0 18.0 1″ 1″ 406 1273 1030 122 >3,600
Replacement
element
·E100(20470/5μm)·X100(25450/10μm)·D100(20000/3μm)·WE100(20450/Only Water absorber)

Pre-Filters for PF20series

 

Above mentioned model are our standard models.

Contact your local distributor for custom made solutions.

Examples of additional features.

*Water glycol version

*Pressure switch and vacuum switch

*Pre-heaters

*Control panel

SS- type

Standard models for the mineral oil <Install elements/M100·20430·βз=929>

Model/Specifications Article nr Motor Flow rate
/min
Thread

BSPT

Dimension

mm

Weight
(Dry)
Tank

capacity

Nr.of

elements

200V 100V Power(KW)·
Cycle(
Hz)
50Hz 60Hz IN OUT W L H kg Liter
CS-SS102-1RQ 2 15271 15273 0.20·50/60 6.0 7.2 1/2 1/2 406 652 885 58 >1,200
CS-SS102-2RQ 4 15272 15273 0.40·50/60 12.0 14.4 3/4 3/4 406 993 885 90 >2,400
CS-SS103-1RQ 3 15281 15285 0.40·50/60 9.0 10.8 1/2 1/2 406 652 1030 61 >1,800
CS-SS103-2RQ 6 15282 15286 0.75·50/60 18.0 18.0 1″ 1″ 406 993 1030 96 >3,600
CS-SS103-3RQ 9 15283 15287 0.75·50/60 24.0 28.8 1″ 1″ 406 1273 1030 130 >5,400
CS-SS103-4RQ 12 15284 15288 1.50·50/60 30.0 36.0 1″ 1″ 406 1526 1030 165 >7,200
Replacement

elements

·E100(20470/5μm)·X100(25450/10μm)·D100(20000/3μm)·WE100(20450/Only Water absorber)

SS -Large capacity type

<Install elements/M300·20520·3μ>

Model/specification Nr.of Article nr Motor Flow rate
/min
Thread

BSPT

Dimension

mm

Weight
(Dry)
Tank

capacity

elements 200V 100V Power(KW)·
Cycle(
Hz)
50Hz 60Hz IN OUT W L H kg Liter
CS-SS305-1RQ 15851 15853 0.75·50/60 30.0 36.0 1″1/4 1″1/4 900 560 1404 200 >7200
CS-SS305-2RQ 15852 15854 1.5·50/60 58.5 70.2 1″1/4 1″1/4 700 1670 1435 300 >15,000
CS-SS315-1RQ 15871 Nothing 2.2·50/60 65.0 78.0 1″1/4 1″1/4 1324 1170 1569 300 >22,500
Replacement
element
E300(20510/5μm)·X300(20512/10μm)·D300(20515/3μm)

 

Above mentioned model are our standard models.

Contact your local distributor for custom made solutions.

Examples of additional features.

*Water glycol version

*Pre-heaters

*Pressure switch and vacuum switch

*Control panel

AL- type

Standard models for the mineral oil <Install elements/M100·20430·βз=929>

Model/Specifications Article nr Motor Flow rate
/min
Thread

BSPT

Dimension

mm

Weight
(Dry)
Tank

capacity

Nr.of

elements

200V 100V Power(KW)·
Cycle(
Hz)
50Hz 60Hz IN OUT W L H kg Liter
CS-AL100-3RQ 3 15365 15360 0.40·50/60 9.0 10.8 1/2 1/2 500 672 650 75 >1,800
CS-AL100-5RQ 5 15570 15560 0.40·50/60 15.0 14.4 3/4 3/4 500 942 650 100 >3,000
CS-AL100-7RQ 7 15770 15560 0.75·50/60 24.0 21.6 1″ 1″ 500 1206 650 125 >4,200
Replacement

elements

·E100(20470/5μm)·X100(25450/10μm)·D100(20000/3μm)·WE100(20450/Only Water absorber)

Models for the water glycol<Install elements/WG100·25470/10μ>

Model/Specifications Article nr Motor Flow rate
/min
Thread

BSPT

Dimension

mm

Weight
(Dry)
Tank

capacity

Nr.of

elements

200V 100V Power(KW)·
Cycle(
Hz)
50Hz 60Hz IN OUT W L H kg Liter
CS-AL100W-3R 3 15400 15390 0.20·50/60 6.0 5.8 1/2 1/2 500 672 650 75 >900
CS-AL100W-5R 5 15690 15590 0.40·50/60 9.0 10.8 3/4 3/4 500 942 650 100 >1,500
CS-AL100W-7R 7 15840 15800 0.45·50/60 15.0 14.4 1″ 1″ 500 1206 650 125 >2,100
Replacement

elements

DWG100(25480/5μm)

Back to Top

AL-PF type

Standard models for the mineral oil<Install elements/M100·20430·βз=929 Install pre-filters/PF20·22289·20μ>

Model/specification Nr.of Article nr Motor Flow rate
/min
Thread

BSPT

Dimension

mm

Weight
(Dry)
Tank

capacity

elements 200V 100V Power(KW)·
Cycle(
Hz)
50Hz 60Hz IN OUT W L H kg Liter
CS-AL100-3RQ-3PF20 15030 15031 0.40·50/60 9.0 10.8 1/2 1/2 500 912 1015 95 >1,800
CS-SU103-2RQ-3PF20 15870 15070 0.40·50/60 15.0 14.4 3/4 3/4 500 1200 1052 120 >3,000
Replacement
element
·E100(20470/5μm)·X100(25450/10μm)·D100(20000/3μm)·WE100(20450/Only Water absorber)

Pre-Filters for PF20series

Above mentioned model are our standard models.

Contact your local distributor for custom made solutions.

Examples of additional features.

*Water glycol version

*Pressure switch and vacuum switch

*Pre-heaters

*Control panel